Quick Links
Design & Tech Services
© Ibstock Plc. 2026

These units contain a post-tensioned stainless steel element. They will support loads as indicated in the table. It is essential that this loads is in one direction and that the head is laid so that the orientation is correct.
Additional requirement:
The 125mm thick Structural Heads (RSH1, 2 and 5) are for use with render.
Please allow an extra 2 weeks for Structural Heads above standard availability for full curing to take place.
All Cast Stone products are UKCA/CE marked where appropriate.
Please contact our team for Declaration of Performance. Email [email protected]
Get in Touch
To speak to a member of our sales team call 0333 234 3434 - opt.1, opt. 3, or send an enquiry.
| Code | A | B | C | D | Max Length | Kg per Lin/M | Allowable Safe Working Load (KN/m) at Max Length | Chamfered |
|---|---|---|---|---|---|---|---|---|
| SH3 | 100 | 140 | 150 | 18 | 1642 | 29 | 9.4 | Yes |
| SH4 | 100 | 215 | 150 | 18 | 2800 | 46 | 4.7 | Yes |
| SH6 | 100 | 290 | 150 | 18 | 2800 | 61 | 4.7 | Yes |
A
100
B
140
C
150
D
18
Max Length
1642
Kg per Lin/M
29
Allowable Safe Working Load (KN/m) at Max Length
9.4
Chamfered
Yes
A
100
B
215
C
150
D
18
Max Length
2800
Kg per Lin/M
46
Allowable Safe Working Load (KN/m) at Max Length
4.7
Chamfered
Yes
A
100
B
290
C
150
D
18
Max Length
2800
Kg per Lin/M
61
Allowable Safe Working Load (KN/m) at Max Length
4.7
Chamfered
Yes